KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Precision Instrument Cases › Anti-Static Lab Equipment Case for Medical

Anti-Static Lab Equipment Case for Medical

Manufacturer

Lab-grade protection, wherever the field work is · Factory direct · Wholesale / OEM / Global supply

Anti-Static Lab Equipment Case for Medical is an engineered protective case in the instrument case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

An instrument case protects precision measuring and testing equipment in transit, emphasizing shock absorption, moisture resistance and custom foam so instruments stay calibrated between lab and field.

Anti-Static Lab Equipment Case for Medical · Precision Instrument Cases — 客信新材料源头工厂

Anti-Static Lab Equipment Case for Medical: Product & Manufacturer Overview

The Anti-Static Lab Equipment Case for Medical can be tailored to your brand and project: case color, silk-print or laser-engraved logo, foam layout and handle/wheel options are all adjustable. kexinMaterials, as the source factory, runs the whole journey from sample approval to mass production, including neutral shipping and OEM private label.

For instrument manufacturers, kexinMaterials runs co-packing programs — we develop a dedicated case and insert from your 3D data and ship in neutral or branded form, lowering warranty damage rates while unifying your delivery image.

Key facts: kexinMaterials builds the Anti-Static Lab Equipment Case for Medical across injection, rotational and blow molding lines with in-house tooling (35–45 days), full OEM/ODM programs, and wholesale tiers at 50/200/500/1000 pcs.

Key Specifications

Shell materialModified PP / ABS / aluminum-frame composite
Protection ratingIP67
InteriorCustom EVA / PU foam / anti-static foam
Pressure reliefAutomatic equalization valve (air freight ready)
FitsSurveying, testing, analysis, telecom, metrology instruments
OptionsHumidity indicator, desiccant chamber, nameplate, co-packing
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
Lab complianceLogger pocket + tamper seal + disinfectant-safe resin

Product Feature Breakdown

ESD-safeLaboratory / sampling

Permanent ESD materials (carbon masterbatch) and topical treatments differ enormously in service life: if Anti-Static Lab Equipment Case for Medical will be washed and reused repeatedly, specify permanent — topical antistats stop working after a few wipe-downs. kexinMaterials supplies permanent ESD bodies as standard.

For specimen transport, regulators scrutinise chain integrity more than shell strength: Anti-Static Lab Equipment Case for Medical needs traceable temperature records, tamper-evident seals and correct biosafety marking. kexinMaterials supplies bodies with data-logger pockets and single-use seal holes.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
ProtectionIP67, thermal-shock verified -40°C↔+71°CPlain cases fail thermal shock
Damping foamEVA/PU/XLPE CNC-cut to instrument shapeGeneric foam under-cushions
ESD & cleanOptional anti-static liner, non-shedding XLPESheds debris onto optics
RigidityABS high surface hardness, high crush strengthPP softens under stacking
MOQFrom 50 pcs, non-standard sizes toolableOften 500 pcs min
CertificationDrop/vibration test reports providedIncomplete docs

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Shell Materials Compared (PP / ABS / PE)

Industry data puts PP (polypropylene) at ~55% of plastic protective-case share — strong chemical resistance, low-temperature toughness and cost efficiency; ABS holds ~30% with harder, glossier surfaces; large thick-wall cases favor rotomolded PE. Plastic/polymer cases together account for 63.7% of the industrial protective case market (2025).

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Typical Applications

  • Surveying instrument field carry
  • Third-party lab on-site sampling
  • Metrology equipment calibration logistics
  • Fiber-optic construction toolkits
  • Laboratory relocation and equipment loans
  • Manufacturer co-packing programs

Product Overview

The kexinMaterials Anti-Static Lab Equipment Case for Medical is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static Lab Equipment Case for Medical can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static Lab Equipment Case for Medical ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static Lab Equipment Case for Medical passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

High-pressure injection molding keeps shell tolerances tight for reliable sealing, and inserts are CNC-cut after drop-simulation checks. Volume co-packing projects follow a PDI inspection routine so cushioning performance stays consistent across batches.

Precision Instrument Cases · Anti-Static Lab Equipment Case for Medical — 客信新材料 kexinMaterials
Precision Instrument Cases · Anti-Static Lab Equipment Case for Medical

Field Case Studies

Metrology institute

600 anti-static liner cases for precision calibrators using non-shedding XLPE; zero scratch incidents in annual off-site checks.

Industrial-sensor maker

3,000 cases CNC-cut to probe shapes, thermal-shock verified -40°C↔+71°C, protecting gear across overseas expos.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Do you make 19-inch rack-mount cases?

Yes. We offer rack-frame protective cases supporting 2U to 8U equipment, with the rack isolated from the shell by shock mounts — suitable for field test systems, communications gear and mobile equipment rooms.

How do you keep instruments in calibration after shipping?

By interrupting the vibration path: high-density EVA is cut to the instrument profile so a 20–30 mm cushion separates it from the shell, with energy-absorbing foam underneath. For high-precision units we can add isolation mounts or a suspended insert to attenuate transport shock within the instrument's tolerance.

Plastic vs aluminum instrument cases?

At equal protection, engineering-plastic cases are lighter, corrosion-free, dent-free and better sealed than most riveted aluminum cases — at lower volume cost.

Do you offer anti-static interiors?

Yes — anti-static foam and conductive EVA with surface resistance in the 10^6–10^9 ohm range for PCBs and electronic modules.

What standard sizes are available?

Our stock molds run from roughly 200 mm internal length for handheld meters up to 800 mm-plus for benchtop instrument transit cases, across more than a dozen size steps. Send the instrument's dimensions and weight and we will match the closest existing mold to avoid tooling cost.

Can the interior be split into layers?

Yes. A common layout puts the main unit on the upper level and cables and accessories below, divided by an EVA tray with pull tabs. Drawer-style or hinged compartments are also available so field crews can reach accessories without unpacking everything.

Key Terms Explained

UN packaging certification
United Nations certification for dangerous-goods packaging, requiring drop, stacking, leakproofness and hydraulic tests plus UN marking. A protective case can serve as inner or outer packaging, but the complete system must be certified separately under UN rules.
Pick-and-pluck foam
Pre-scored cubed foam that the user tears out cube by cube to form pockets around the equipment. It needs no tooling, ships fast and can be reconfigured, but offers less precision and support than CNC-cut EVA.
Drop test
A loaded case is released from a defined height—1.2 m is common in this industry—onto six faces and eight corners in sequence, then inspected for shell cracking, latch failure and loss of seal. It is the most direct measure of a case's impact resistance.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Does good insulation mean specimen-transport compliance?

No. Compliant specimen shipping requires verifiable end-to-end temperature records, triple packaging per UN3373 or UN2814, plus correct labelling and documentation. Insulation is only one means of holding the temperature band — missing records or the wrong packaging class still fails inspection.

Related Keywords

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.