KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Precision Instrument Cases › Anti-Static Lab Equipment Case for Lab

Anti-Static Lab Equipment Case for Lab

Manufacturer

Lab-grade protection, wherever the field work is · Factory direct · Wholesale / OEM / Global supply

Anti-Static Lab Equipment Case for Lab is an engineered protective case in the instrument case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

An instrument case protects precision measuring and testing equipment in transit, emphasizing shock absorption, moisture resistance and custom foam so instruments stay calibrated between lab and field.

Anti-Static Lab Equipment Case for Lab · Precision Instrument Cases — 客信新材料源头工厂

Anti-Static Lab Equipment Case for Lab: Product & Manufacturer Overview

Test instruments and surveying equipment are sensitive to shock, vibration and condensation. A proper Anti-Static Lab Equipment Case for Lab extends laboratory-grade protection into transit and field use. kexinMaterials combines IP67 molded shells with engineered cushioning systems for the instrumentation industry.

From total stations and spectrometers to flaw detectors, kexinMaterials has built the Anti-Static Lab Equipment Case for Lab for thousands of instrument models, with an insert database spanning surveying, environmental monitoring, NDT and telecom engineering.

Key facts: kexinMaterials builds the Anti-Static Lab Equipment Case for Lab across injection, rotational and blow molding lines with in-house tooling (35–45 days), full OEM/ODM programs, and wholesale tiers at 50/200/500/1000 pcs.

Key Specifications

Shell materialModified PP / ABS / aluminum-frame composite
Protection ratingIP67
InteriorCustom EVA / PU foam / anti-static foam
Pressure reliefAutomatic equalization valve (air freight ready)
FitsSurveying, testing, analysis, telecom, metrology instruments
OptionsHumidity indicator, desiccant chamber, nameplate, co-packing
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
Lab complianceLogger pocket + tamper seal + disinfectant-safe resin

Product Feature Breakdown

ESD-safeLaboratory / sampling

ESD performance on Anti-Static Lab Equipment Case for Lab is graded by surface resistivity: conductive 10³–10⁵Ω, dissipative 10⁶–10⁹Ω, antistatic 10⁹–10¹¹Ω. Component handling normally calls for the dissipative band, avoiding the high transient current of a fast discharge. kexinMaterials configures to ANSI/ESD S541.

Laboratory cases must survive cleaning and disinfection: if Anti-Static Lab Equipment Case for Lab will face repeated sodium-hypochlorite or alcohol wipe-down, specify PP or medical-grade ABS rather than commodity PS, and avoid coated surfaces. kexinMaterials provides a chemical-resistance chart for selection.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
ProtectionIP67, thermal-shock verified -40°C↔+71°CPlain cases fail thermal shock
Damping foamEVA/PU/XLPE CNC-cut to instrument shapeGeneric foam under-cushions
ESD & cleanOptional anti-static liner, non-shedding XLPESheds debris onto optics
RigidityABS high surface hardness, high crush strengthPP softens under stacking
MOQFrom 50 pcs, non-standard sizes toolableOften 500 pcs min
CertificationDrop/vibration test reports providedIncomplete docs

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Shell Materials Compared (PP / ABS / PE)

Industry data puts PP (polypropylene) at ~55% of plastic protective-case share — strong chemical resistance, low-temperature toughness and cost efficiency; ABS holds ~30% with harder, glossier surfaces; large thick-wall cases favor rotomolded PE. Plastic/polymer cases together account for 63.7% of the industrial protective case market (2025).

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Typical Applications

  • Surveying instrument field carry
  • Third-party lab on-site sampling
  • Metrology equipment calibration logistics
  • Fiber-optic construction toolkits
  • Laboratory relocation and equipment loans
  • Manufacturer co-packing programs

Product Overview

The kexinMaterials Anti-Static Lab Equipment Case for Lab is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static Lab Equipment Case for Lab can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static Lab Equipment Case for Lab ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static Lab Equipment Case for Lab passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

High-pressure injection molding keeps shell tolerances tight for reliable sealing, and inserts are CNC-cut after drop-simulation checks. Volume co-packing projects follow a PDI inspection routine so cushioning performance stays consistent across batches.

Precision Instrument Cases · Anti-Static Lab Equipment Case for Lab — 客信新材料 kexinMaterials
Precision Instrument Cases · Anti-Static Lab Equipment Case for Lab

Field Case Studies

Metrology institute

600 anti-static liner cases for precision calibrators using non-shedding XLPE; zero scratch incidents in annual off-site checks.

Industrial-sensor maker

3,000 cases CNC-cut to probe shapes, thermal-shock verified -40°C↔+71°C, protecting gear across overseas expos.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can the case be made moisture-proof or hold desiccant?

Yes. We commonly mold a desiccant pocket into the insert and combine it with IP67 sealing for long-term dryness. For high-value stored instruments we can add humidity indicator cards or a breather-valve version so you can read the internal condition at a glance.

Will air freight pressure lock the case shut?

No. The automatic pressure equalization valve balances internal pressure while keeping the seal waterproof.

How is a custom insert made?

Send 3D data, dimensioned photos or a sample unit. We design the cutout layout, confirm an insert sample with you, then run production. Common models ship from existing data.

How do you protect an instrument's display panel?

The insert is relieved above the screen so nothing touches the display — load is carried only on the chassis frame, preventing lid pressure from reaching the glass. A soft pad can be added in the lid for two-way protection where needed.

Do you make 19-inch rack-mount cases?

Yes. We offer rack-frame protective cases supporting 2U to 8U equipment, with the rack isolated from the shell by shock mounts — suitable for field test systems, communications gear and mobile equipment rooms.

How do I place an order or get a quote?

For retail and small orders, visit our online store. For wholesale, OEM or export, send the case type, quantity and deadline — kexinMaterials returns a tiered quote and container plan within 24 hours.

Key Terms Explained

EVA foam insert
Ethylene-vinyl acetate closed-cell foam: dense, resilient, CNC-machinable and resistant to permanent compression set. In protective cases it is cut to the equipment profile and is the preferred lining for precision instruments and high-value gear.
Salt fog test
Continuous salt spray exposure per GB/T 10125 or ASTM B117 to assess corrosion resistance of metals and coatings. Case shells are inherently salt-resistant, so the test really evaluates hinges, latches and fasteners — critical for marine applications.
UN packaging certification
United Nations certification for dangerous-goods packaging, requiring drop, stacking, leakproofness and hydraulic tests plus UN marking. A protective case can serve as inner or outer packaging, but the complete system must be certified separately under UN rules.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Does good insulation mean specimen-transport compliance?

No. Compliant specimen shipping requires verifiable end-to-end temperature records, triple packaging per UN3373 or UN2814, plus correct labelling and documentation. Insulation is only one means of holding the temperature band — missing records or the wrong packaging class still fails inspection.

Related Keywords

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.