KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Stackable Diagnostic Case

Stackable Diagnostic Case

Manufacturer

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Stackable Diagnostic Case is an engineered protective case in the medical case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Stackable Diagnostic Case · Medical & Cold Chain Cases — 客信新材料源头工厂

Stackable Diagnostic Case: Product & Manufacturer Overview

Reliability in a Stackable Diagnostic Case comes from structure: kexinMaterials combines PU-foamed insulation walls with sealed shells and dedicated ice-pack bays, holding 2–8°C for 48+ hours under standard load (model and ambient dependent), with mounting points for temperature data loggers.

Transporting medical devices, emergency supplies and biological samples demands both physical protection and temperature control. The kexinMaterials Stackable Diagnostic Case range spans first-aid cases, vaccine cold boxes and specimen carriers, built with medical-grade liners and insulated structures for hospitals, CDCs and pharma logistics.

Key facts: Stackable Diagnostic Case sourcing facts: factory-direct from Guangdong, China; sealing up to IP67; service range -40°C to +80°C; CNC-cut EVA interiors; logo printing/engraving; factory audits and third-party QC welcome.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
StackingInterlocking location, 1200×1000 pallet compatible

Product Feature Breakdown

Stackable / interlocking

Stacked applications must be assessed dynamically: in forklift handling and vehicle braking, Stackable Diagnostic Case carries lateral inertial loads, so incline-impact or vibration-table testing is needed, not just static compression. kexinMaterials can supply ISTA 3E simulated-transport reports.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

Standards & Industry Data

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Product Overview

The kexinMaterials Stackable Diagnostic Case is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Stackable Diagnostic Case can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Stackable Diagnostic Case ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Stackable Diagnostic Case passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Stackable Diagnostic Case — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Stackable Diagnostic Case

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can a data logger be installed?

Yes — a fixed logger bay inside plus an external-read window option, compatible with mainstream USB and Bluetooth loggers.

How long can 2–8°C be maintained?

Depends on model, ice-pack setup and ambient: standard setups hold 48+ hours at 35°C ambient. We provide measured curves for your actual load profile.

Can medical cases be wiped with disinfectant?

Yes. The modified PP/ABS shell tolerates 75% alcohol, chlorine-based and quaternary ammonium disinfectant wipes; avoid prolonged soaking in strong oxidizers. Inserts can be specified as removable, washable EVA or medical-grade foam for routine cleaning.

Can you build cold-chain or insulated versions?

Yes. We offer PU-foam insulated shells that hold 2–8 °C or -20 °C ranges for short-haul transport when combined with ice packs or phase-change coolant. A mounting pocket and read-out window for a temperature logger can be pre-installed.

Can the interior be zoned by clinical function?

Yes. A common layout separates resuscitation, airway, trauma and pharmacy items with color-coded bands and clear elastic pockets so contents are visible and restocking is orderly. Layouts can be rebuilt around your hospital's protocol, with a checklist printed inside the lid.

Can you support our GDP/GSP validation?

Yes — insulation test data, loading recommendations and validation templates to complete your transport qualification files.

Key Terms Explained

MOQ (minimum order quantity)
The smallest order a supplier will accept. For protective cases with existing tooling, MOQ is typically 50–100 pieces; newly tooled custom projects carry higher minimums to amortize mold and setup costs.
MIL-STD-810
A US Department of Defense standard for environmental engineering considerations and laboratory tests, defining procedures for drop, vibration, thermal shock, salt fog and humidity. Protective cases are commonly validated against Method 516 (shock) and Method 514 (vibration).
IP67 rating
An ingress protection code from IEC 60529. The first digit 6 means dust-tight; the second digit 7 means no water ingress during 30 minutes at 1 m depth. It is the mainstream sealing benchmark for protective cases covering outdoor, marine and emergency short-immersion use.

Common Misconceptions

Does stackable in storage mean stackable in transit?

They are different problems. Static stacking only tests compressive strength, whereas transport stacking adds vibration, lateral loads from hard braking, and resonant amplification. Plenty of cases pass compression yet suffer lid collapse or whole-stack toppling in the real lane, precisely because interlocking features and strapping schemes were omitted.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.