KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › OEM First Aid Case for Lab

OEM First Aid Case for Lab

OEM/ODM

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

OEM First Aid Case for Lab: send your equipment dimensions or 3D files and kexinMaterials returns a free case-selection and foam-layout proposal, prototypes from its in-house tool shop, and supports logo, color and packaging customization.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

OEM First Aid Case for Lab · Medical & Cold Chain Cases — 客信新材料源头工厂

OEM First Aid Case for Lab: Product & Manufacturer Overview

For device manufacturers and pharma distributors, kexinMaterials offers OEM programs on the OEM First Aid Case for Lab: custom inserts sized to your device, insulation test data for cold-chain validation, and logger accessories for GDP/GSP compliance — one supplier from registration to operations.

Pre-hospital and disaster response add two more requirements: light weight and instant access. kexinMaterials first-aid cases use lightweight compounds and modular layered interiors, one-hand carriable with zone-visible supplies to save golden minutes.

Key facts: OEM First Aid Case for Lab sourcing facts: factory-direct from Guangdong, China; sealing up to IP67; service range -40°C to +80°C; CNC-cut EVA interiors; logo printing/engraving; factory audits and third-party QC welcome.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
Lab complianceLogger pocket + tamper seal + disinfectant-safe resin

Product Feature Breakdown

Laboratory / sampling

For specimen transport, regulators scrutinise chain integrity more than shell strength: OEM First Aid Case for Lab needs traceable temperature records, tamper-evident seals and correct biosafety marking. kexinMaterials supplies bodies with data-logger pockets and single-use seal holes.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

Standards & Industry Data

Export Compliance Essentials

EU-bound cases require CE marking and REACH compliance (phthalates such as DEHP/DBP each below 0.1% in soft parts); hard cases sold via Amazon FBA need ISTA 3A transit-drop certification; shipping drones or devices with lithium batteries additionally involves UN38.3 and IATA rules. A legitimate source factory provides these test reports directly.

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Sourcing & Selection Tips · OEM / private label

  • OEM First Aid Case for Lab is available for OEM/private-label: kexinMaterials customizes shell, insert and packaging so finished-goods brands turn protective packaging into part of the product experience.
  • OEM programs can reuse kexinMaterials's existing molds to avoid tooling fees, with branded silk-screen, CNC-cut inserts and manuals to shorten time-to-market.

OEM / ODM Custom Manufacturing

kexinMaterials runs full OEM/ODM programs on the OEM First Aid Case for Lab: drawing/sample quotation, 3D structural design, in-house tooling (35–45 days), pilot runs and mass production — under NDA throughout.

The standard private-label flow for the OEM First Aid Case for Lab: requirement review → proposal & quote (1–3 days) → sample approval (7–15 days) → production (15–30 days) → QC & shipment. Logos via silk print, laser engraving, hot stamping or in-mold labeling.

Need speed instead of tooling? Choose tooling-free private label: adopt an existing kexinMaterials mold, switch colors and branding, and launch from just 100 pcs — the fastest route for new case brands.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · OEM First Aid Case for Lab — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · OEM First Aid Case for Lab

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can a data logger be installed?

Yes — a fixed logger bay inside plus an external-read window option, compatible with mainstream USB and Bluetooth loggers.

How long can 2–8°C be maintained?

Depends on model, ice-pack setup and ambient: standard setups hold 48+ hours at 35°C ambient. We provide measured curves for your actual load profile.

Can the interior be zoned by clinical function?

Yes. A common layout separates resuscitation, airway, trauma and pharmacy items with color-coded bands and clear elastic pockets so contents are visible and restocking is orderly. Layouts can be rebuilt around your hospital's protocol, with a checklist printed inside the lid.

Can medical cases be wiped with disinfectant?

Yes. The modified PP/ABS shell tolerates 75% alcohol, chlorine-based and quaternary ammonium disinfectant wipes; avoid prolonged soaking in strong oxidizers. Inserts can be specified as removable, washable EVA or medical-grade foam for routine cleaning.

What disinfection do liners tolerate?

Food-grade EVA and medical PE liners tolerate 75% alcohol and chlorine-based wipes, and lift out for full washing.

What compliance requirements apply to medical transport cases?

In China, storage and transport conditions, temperature/humidity records and cleaning are governed by medical device distribution quality rules; exports follow the destination country's registration requirements. As an accessory, the case ships with material safety notes and cleaning validation guidance to support your documentation.

Key Terms Explained

OEM / ODM
OEM means manufacturing to the customer's design under the customer's brand; ODM means the factory designs the product and the customer rebrands it. In case sourcing, private-labeling an existing shell is OEM, while commissioning a new shell and interior design is closer to ODM.
Gasket
The elastomeric ring—usually silicone or EPDM—seated in the lid-to-base joint. Latch pressure deforms it to fill the mating gap, making it the core component behind an IP67 seal and a replaceable wear part.
Pick-and-pluck foam
Pre-scored cubed foam that the user tears out cube by cube to form pockets around the equipment. It needs no tooling, ships fast and can be reconfigured, but offers less precision and support than CNC-cut EVA.

Common Misconceptions

Does good insulation mean specimen-transport compliance?

No. Compliant specimen shipping requires verifiable end-to-end temperature records, triple packaging per UN3373 or UN2814, plus correct labelling and documentation. Insulation is only one means of holding the temperature band — missing records or the wrong packaging class still fails inspection.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.