Specs

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Medium First Aid Case: confirm internal dimensions first (equipment size plus foam allowance), then protection rating (IP67 is the benchmark) and shell material (PP for value, ABS for surface hardness, rotomolded PE for large sizes). Custom sizes available via tooling.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Medium First Aid Case · Medical & Cold Chain Cases — 客信新材料源头工厂

Medium First Aid Case: Product & Manufacturer Overview

For buyers, the true cost of a Medium First Aid Case is more than unit price: carton specs shape freight, and spare parts and replenishment shape long-term use. kexinMaterials optimizes container loading and ships wear-part kits with volume orders to lower your total cost of ownership.

Reliability in a Medium First Aid Case comes from structure: kexinMaterials combines PU-foamed insulation walls with sealed shells and dedicated ice-pack bays, holding 2–8°C for 48+ hours under standard load (model and ambient dependent), with mounting points for temperature data loggers.

Key facts: The Medium First Aid Case is manufactured factory-direct by KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials): IP67 options, MOQ 50 pcs on stock models, samples in 7–15 days, production in 15–30 days, exporting to 8 major markets.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

Standards & Industry Data

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Sizing & Selection Guide

To size a Medium First Aid Case, measure the largest 3D dimensions of the payload and allow 30–50 mm per side for foam, then match against internal case dimensions. Above 30 kg payloads, add wheels and reinforced bases.

kexinMaterials stocks a full size run from personal cases to large transit trunks with published internal dimensions; if nothing fits, we evaluate mold revisions or new tooling — selection advice is free.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Medium First Aid Case — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Medium First Aid Case

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can you support our GDP/GSP validation?

Yes — insulation test data, loading recommendations and validation templates to complete your transport qualification files.

Can medical cases be wiped with disinfectant?

Yes. The modified PP/ABS shell tolerates 75% alcohol, chlorine-based and quaternary ammonium disinfectant wipes; avoid prolonged soaking in strong oxidizers. Inserts can be specified as removable, washable EVA or medical-grade foam for routine cleaning.

What compliance requirements apply to medical transport cases?

In China, storage and transport conditions, temperature/humidity records and cleaning are governed by medical device distribution quality rules; exports follow the destination country's registration requirements. As an accessory, the case ships with material safety notes and cleaning validation guidance to support your documentation.

Can the interior be zoned by clinical function?

Yes. A common layout separates resuscitation, airway, trauma and pharmacy items with color-coded bands and clear elastic pockets so contents are visible and restocking is orderly. Layouts can be rebuilt around your hospital's protocol, with a checklist printed inside the lid.

Can a data logger be installed?

Yes — a fixed logger bay inside plus an external-read window option, compatible with mainstream USB and Bluetooth loggers.

How long can 2–8°C be maintained?

Depends on model, ice-pack setup and ambient: standard setups hold 48+ hours at 35°C ambient. We provide measured curves for your actual load profile.

Key Terms Explained

Rotational molding
A process in which polyethylene powder is heated inside a biaxially rotating mold so the melt coats the cavity evenly. It yields seamless, tough walls, supports double-wall sandwich construction and uses low-cost tooling — ideal for large and oversize cases.
Injection molding
Molten plastic is injected under high pressure into a steel mold and cooled. It delivers tight tolerances, fine surface finish and fast cycles at low piece cost, but requires higher tooling investment — best for volume production of small and mid-size cases.
UN packaging certification
United Nations certification for dangerous-goods packaging, requiring drop, stacking, leakproofness and hydraulic tests plus UN marking. A protective case can serve as inner or outer packaging, but the complete system must be certified separately under UN rules.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.