KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Extra Large Medical Case

Extra Large Medical Case

Specs

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Extra Large Medical Case: confirm internal dimensions first (equipment size plus foam allowance), then protection rating (IP67 is the benchmark) and shell material (PP for value, ABS for surface hardness, rotomolded PE for large sizes). Custom sizes available via tooling.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Extra Large Medical Case · Medical & Cold Chain Cases — 客信新材料源头工厂

Extra Large Medical Case: Product & Manufacturer Overview

Pre-hospital and disaster response add two more requirements: light weight and instant access. kexinMaterials first-aid cases use lightweight compounds and modular layered interiors, one-hand carriable with zone-visible supplies to save golden minutes.

Transporting medical devices, emergency supplies and biological samples demands both physical protection and temperature control. The kexinMaterials Extra Large Medical Case range spans first-aid cases, vaccine cold boxes and specimen carriers, built with medical-grade liners and insulated structures for hospitals, CDCs and pharma logistics.

Key facts: kexinMaterials builds the Extra Large Medical Case across injection, rotational and blow molding lines with in-house tooling (35–45 days), full OEM/ODM programs, and wholesale tiers at 50/200/500/1000 pcs.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

Standards & Industry Data

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Shell Materials Compared (PP / ABS / PE)

Industry data puts PP (polypropylene) at ~55% of plastic protective-case share — strong chemical resistance, low-temperature toughness and cost efficiency; ABS holds ~30% with harder, glossier surfaces; large thick-wall cases favor rotomolded PE. Plastic/polymer cases together account for 63.7% of the industrial protective case market (2025).

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Sizing & Selection Guide

To size a Extra Large Medical Case, measure the largest 3D dimensions of the payload and allow 30–50 mm per side for foam, then match against internal case dimensions. Above 30 kg payloads, add wheels and reinforced bases.

kexinMaterials stocks a full size run from personal cases to large transit trunks with published internal dimensions; if nothing fits, we evaluate mold revisions or new tooling — selection advice is free.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Extra Large Medical Case — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Extra Large Medical Case

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

How long can 2–8°C be maintained?

Depends on model, ice-pack setup and ambient: standard setups hold 48+ hours at 35°C ambient. We provide measured curves for your actual load profile.

Can medical cases be wiped with disinfectant?

Yes. The modified PP/ABS shell tolerates 75% alcohol, chlorine-based and quaternary ammonium disinfectant wipes; avoid prolonged soaking in strong oxidizers. Inserts can be specified as removable, washable EVA or medical-grade foam for routine cleaning.

Can the interior be zoned by clinical function?

Yes. A common layout separates resuscitation, airway, trauma and pharmacy items with color-coded bands and clear elastic pockets so contents are visible and restocking is orderly. Layouts can be rebuilt around your hospital's protocol, with a checklist printed inside the lid.

Can it be made lighter for single-person carry?

Yes. Optimizing wall-thickness distribution, using high-flow modified resins and honeycomb ribbing cuts 15–25% of weight while keeping strength, combined with ergonomic handles and a shoulder strap for longer one-person carries.

Can you build cold-chain or insulated versions?

Yes. We offer PU-foam insulated shells that hold 2–8 °C or -20 °C ranges for short-haul transport when combined with ice packs or phase-change coolant. A mounting pocket and read-out window for a temperature logger can be pre-installed.

What disinfection do liners tolerate?

Food-grade EVA and medical PE liners tolerate 75% alcohol and chlorine-based wipes, and lift out for full washing.

Key Terms Explained

Salt fog test
Continuous salt spray exposure per GB/T 10125 or ASTM B117 to assess corrosion resistance of metals and coatings. Case shells are inherently salt-resistant, so the test really evaluates hinges, latches and fasteners — critical for marine applications.
Drop test
A loaded case is released from a defined height—1.2 m is common in this industry—onto six faces and eight corners in sequence, then inspected for shell cracking, latch failure and loss of seal. It is the most direct measure of a case's impact resistance.
ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store