KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Precision Instrument Cases › Anti-Static Test Equipment Case for Medical

Anti-Static Test Equipment Case for Medical

Manufacturer

Lab-grade protection, wherever the field work is · Factory direct · Wholesale / OEM / Global supply

Anti-Static Test Equipment Case for Medical is an engineered protective case in the instrument case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

An instrument case protects precision measuring and testing equipment in transit, emphasizing shock absorption, moisture resistance and custom foam so instruments stay calibrated between lab and field.

Anti-Static Test Equipment Case for Medical · Precision Instrument Cases — 客信新材料源头工厂

Anti-Static Test Equipment Case for Medical: Product & Manufacturer Overview

For buyers, the true cost of a Anti-Static Test Equipment Case for Medical is more than unit price: carton specs shape freight, and spare parts and replenishment shape long-term use. kexinMaterials optimizes container loading and ships wear-part kits with volume orders to lower your total cost of ownership.

For instrument manufacturers, kexinMaterials runs co-packing programs — we develop a dedicated case and insert from your 3D data and ship in neutral or branded form, lowering warranty damage rates while unifying your delivery image.

Key facts: Anti-Static Test Equipment Case for Medical sourcing facts: factory-direct from Guangdong, China; sealing up to IP67; service range -40°C to +80°C; CNC-cut EVA interiors; logo printing/engraving; factory audits and third-party QC welcome.

Key Specifications

Shell materialModified PP / ABS / aluminum-frame composite
Protection ratingIP67
InteriorCustom EVA / PU foam / anti-static foam
Pressure reliefAutomatic equalization valve (air freight ready)
FitsSurveying, testing, analysis, telecom, metrology instruments
OptionsHumidity indicator, desiccant chamber, nameplate, co-packing
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
Lab complianceLogger pocket + tamper seal + disinfectant-safe resin

Product Feature Breakdown

ESD-safeLaboratory / sampling

Permanent ESD materials (carbon masterbatch) and topical treatments differ enormously in service life: if Anti-Static Test Equipment Case for Medical will be washed and reused repeatedly, specify permanent — topical antistats stop working after a few wipe-downs. kexinMaterials supplies permanent ESD bodies as standard.

For specimen transport, regulators scrutinise chain integrity more than shell strength: Anti-Static Test Equipment Case for Medical needs traceable temperature records, tamper-evident seals and correct biosafety marking. kexinMaterials supplies bodies with data-logger pockets and single-use seal holes.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
ProtectionIP67, thermal-shock verified -40°C↔+71°CPlain cases fail thermal shock
Damping foamEVA/PU/XLPE CNC-cut to instrument shapeGeneric foam under-cushions
ESD & cleanOptional anti-static liner, non-shedding XLPESheds debris onto optics
RigidityABS high surface hardness, high crush strengthPP softens under stacking
MOQFrom 50 pcs, non-standard sizes toolableOften 500 pcs min
CertificationDrop/vibration test reports providedIncomplete docs

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Typical Applications

  • Surveying instrument field carry
  • Third-party lab on-site sampling
  • Metrology equipment calibration logistics
  • Fiber-optic construction toolkits
  • Laboratory relocation and equipment loans
  • Manufacturer co-packing programs

Product Overview

The kexinMaterials Anti-Static Test Equipment Case for Medical is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static Test Equipment Case for Medical can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static Test Equipment Case for Medical ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static Test Equipment Case for Medical passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

High-pressure injection molding keeps shell tolerances tight for reliable sealing, and inserts are CNC-cut after drop-simulation checks. Volume co-packing projects follow a PDI inspection routine so cushioning performance stays consistent across batches.

Precision Instrument Cases · Anti-Static Test Equipment Case for Medical — 客信新材料 kexinMaterials
Precision Instrument Cases · Anti-Static Test Equipment Case for Medical

Field Case Studies

Metrology institute

600 anti-static liner cases for precision calibrators using non-shedding XLPE; zero scratch incidents in annual off-site checks.

Industrial-sensor maker

3,000 cases CNC-cut to probe shapes, thermal-shock verified -40°C↔+71°C, protecting gear across overseas expos.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

What standard sizes are available?

Our stock molds run from roughly 200 mm internal length for handheld meters up to 800 mm-plus for benchtop instrument transit cases, across more than a dozen size steps. Send the instrument's dimensions and weight and we will match the closest existing mold to avoid tooling cost.

Plastic vs aluminum instrument cases?

At equal protection, engineering-plastic cases are lighter, corrosion-free, dent-free and better sealed than most riveted aluminum cases — at lower volume cost.

Can the case be made moisture-proof or hold desiccant?

Yes. We commonly mold a desiccant pocket into the insert and combine it with IP67 sealing for long-term dryness. For high-value stored instruments we can add humidity indicator cards or a breather-valve version so you can read the internal condition at a glance.

How do you keep instruments in calibration after shipping?

By interrupting the vibration path: high-density EVA is cut to the instrument profile so a 20–30 mm cushion separates it from the shell, with energy-absorbing foam underneath. For high-precision units we can add isolation mounts or a suspended insert to attenuate transport shock within the instrument's tolerance.

How is a custom insert made?

Send 3D data, dimensioned photos or a sample unit. We design the cutout layout, confirm an insert sample with you, then run production. Common models ship from existing data.

Do you make 19-inch rack-mount cases?

Yes. We offer rack-frame protective cases supporting 2U to 8U equipment, with the rack isolated from the shell by shock mounts — suitable for field test systems, communications gear and mobile equipment rooms.

Key Terms Explained

ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.
IP67 rating
An ingress protection code from IEC 60529. The first digit 6 means dust-tight; the second digit 7 means no water ingress during 30 minutes at 1 m depth. It is the mainstream sealing benchmark for protective cases covering outdoor, marine and emergency short-immersion use.
UN packaging certification
United Nations certification for dangerous-goods packaging, requiring drop, stacking, leakproofness and hydraulic tests plus UN marking. A protective case can serve as inner or outer packaging, but the complete system must be certified separately under UN rules.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Does good insulation mean specimen-transport compliance?

No. Compliant specimen shipping requires verifiable end-to-end temperature records, triple packaging per UN3373 or UN2814, plus correct labelling and documentation. Insulation is only one means of holding the temperature band — missing records or the wrong packaging class still fails inspection.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.