KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Anti-Static Medical Case for Rescue

Anti-Static Medical Case for Rescue

Manufacturer

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Anti-Static Medical Case for Rescue is an engineered protective case in the medical case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Anti-Static Medical Case for Rescue · Medical & Cold Chain Cases — 客信新材料源头工厂

Anti-Static Medical Case for Rescue: Product & Manufacturer Overview

For buyers, the true cost of a Anti-Static Medical Case for Rescue is more than unit price: carton specs shape freight, and spare parts and replenishment shape long-term use. kexinMaterials optimizes container loading and ships wear-part kits with volume orders to lower your total cost of ownership.

Pre-hospital and disaster response add two more requirements: light weight and instant access. kexinMaterials first-aid cases use lightweight compounds and modular layered interiors, one-hand carriable with zone-visible supplies to save golden minutes.

Key facts: The Anti-Static Medical Case for Rescue is manufactured factory-direct by KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials): IP67 options, MOQ 50 pcs on stock models, samples in 7–15 days, production in 15–30 days, exporting to 8 major markets.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
Emergency designOne-hand latches, >100° lid, reflective marking

Product Feature Breakdown

ESD-safeEmergency response

Permanent ESD materials (carbon masterbatch) and topical treatments differ enormously in service life: if Anti-Static Medical Case for Rescue will be washed and reused repeatedly, specify permanent — topical antistats stop working after a few wipe-downs. kexinMaterials supplies permanent ESD bodies as standard.

In emergency response, access speed is the primary metric for Anti-Static Medical Case for Rescue: latches must work one-handed with gloves, the lid must open beyond 100° so it cannot fall back, and the insert must be laid out by treatment protocol rather than item category. kexinMaterials builds the retrieval sequence around a customer's own SOP.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Product Overview

The kexinMaterials Anti-Static Medical Case for Rescue is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static Medical Case for Rescue can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static Medical Case for Rescue ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static Medical Case for Rescue passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Anti-Static Medical Case for Rescue — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Anti-Static Medical Case for Rescue

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can the case be mounted in an ambulance?

Yes. We supply versions with mounting bases or clips that mate with stretcher frames and cabin wall fixings so the case cannot shift in transit, plus anti-slip feet and quick-release straps for carrying once on scene.

What compliance requirements apply to medical transport cases?

In China, storage and transport conditions, temperature/humidity records and cleaning are governed by medical device distribution quality rules; exports follow the destination country's registration requirements. As an accessory, the case ships with material safety notes and cleaning validation guidance to support your documentation.

Can you support our GDP/GSP validation?

Yes — insulation test data, loading recommendations and validation templates to complete your transport qualification files.

What disinfection do liners tolerate?

Food-grade EVA and medical PE liners tolerate 75% alcohol and chlorine-based wipes, and lift out for full washing.

Can the interior be zoned by clinical function?

Yes. A common layout separates resuscitation, airway, trauma and pharmacy items with color-coded bands and clear elastic pockets so contents are visible and restocking is orderly. Layouts can be rebuilt around your hospital's protocol, with a checklist printed inside the lid.

Are you a factory or a trading company?

kexinMaterials is a source factory for engineered plastic cases based in Guangdong, China, with injection, rotational and blow molding lines and an in-house tool shop. Factory audits and video tours are welcome.

Key Terms Explained

IP67 rating
An ingress protection code from IEC 60529. The first digit 6 means dust-tight; the second digit 7 means no water ingress during 30 minutes at 1 m depth. It is the mainstream sealing benchmark for protective cases covering outdoor, marine and emergency short-immersion use.
Custom tooling
Building a dedicated mold for a specific case design, giving an exact fit in size and structure. Compared with selecting an existing mold it takes longer (roughly 20–30 days for aluminum tooling, longer for steel) and costs more up front — worthwhile for sustained volume.
Drop test
A loaded case is released from a defined height—1.2 m is common in this industry—onto six faces and eight corners in sequence, then inspected for shell cracking, latch failure and loss of seal. It is the most direct measure of a case's impact resistance.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Is a rescue case just a tool case with different contents?

The design logic is entirely different. Tool cases optimise volumetric efficiency; rescue cases optimise seconds-to-access and missing-item visibility — one-handed latches, wide lid opening, protocol-ordered layout, colour zoning and inventory windows. In an emergency, not finding an item is more damaging than not carrying it, and that drives the structural difference.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.