KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Anti-Static ESD Surgical Instrument Case for Surveying

Anti-Static ESD Surgical Instrument Case for Surveying

Manufacturer

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Anti-Static ESD Surgical Instrument Case for Surveying is an engineered protective case in the medical case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Anti-Static ESD Surgical Instrument Case for Surveying · Medical & Cold Chain Cases — 客信新材料源头工厂

Anti-Static ESD Surgical Instrument Case for Surveying: Product & Manufacturer Overview

Transporting medical devices, emergency supplies and biological samples demands both physical protection and temperature control. The kexinMaterials Anti-Static ESD Surgical Instrument Case for Surveying range spans first-aid cases, vaccine cold boxes and specimen carriers, built with medical-grade liners and insulated structures for hospitals, CDCs and pharma logistics.

The Anti-Static ESD Surgical Instrument Case for Surveying can be tailored to your brand and project: case color, silk-print or laser-engraved logo, foam layout and handle/wheel options are all adjustable. kexinMaterials, as the source factory, runs the whole journey from sample approval to mass production, including neutral shipping and OEM private label.

Key facts: kexinMaterials builds the Anti-Static ESD Surgical Instrument Case for Surveying across injection, rotational and blow molding lines with in-house tooling (35–45 days), full OEM/ODM programs, and wholesale tiers at 50/200/500/1000 pcs.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
Optics protectionSuspended mounting + desiccant bay (RH 40–50%)

Product Feature Breakdown

ESD-safeOptics

ESD performance on Anti-Static ESD Surgical Instrument Case for Surveying is graded by surface resistivity: conductive 10³–10⁵Ω, dissipative 10⁶–10⁹Ω, antistatic 10⁹–10¹¹Ω. Component handling normally calls for the dissipative band, avoiding the high transient current of a fast discharge. kexinMaterials configures to ANSI/ESD S541.

Fungus is the primary threat to glass: hold internal RH at 40–50% inside Anti-Static ESD Surgical Instrument Case for Surveying with replaceable desiccant and an indicator card, and inspect quarterly during long-term storage. kexinMaterials offers desiccant compartments with a viewing window.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Shell Materials Compared (PP / ABS / PE)

Industry data puts PP (polypropylene) at ~55% of plastic protective-case share — strong chemical resistance, low-temperature toughness and cost efficiency; ABS holds ~30% with harder, glossier surfaces; large thick-wall cases favor rotomolded PE. Plastic/polymer cases together account for 63.7% of the industrial protective case market (2025).

Export Compliance Essentials

EU-bound cases require CE marking and REACH compliance (phthalates such as DEHP/DBP each below 0.1% in soft parts); hard cases sold via Amazon FBA need ISTA 3A transit-drop certification; shipping drones or devices with lithium batteries additionally involves UN38.3 and IATA rules. A legitimate source factory provides these test reports directly.

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Product Overview

The kexinMaterials Anti-Static ESD Surgical Instrument Case for Surveying is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static ESD Surgical Instrument Case for Surveying can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static ESD Surgical Instrument Case for Surveying ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static ESD Surgical Instrument Case for Surveying passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Anti-Static ESD Surgical Instrument Case for Surveying — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Anti-Static ESD Surgical Instrument Case for Surveying

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

What disinfection do liners tolerate?

Food-grade EVA and medical PE liners tolerate 75% alcohol and chlorine-based wipes, and lift out for full washing.

How do I place an order or get a quote?

For retail and small orders, visit our online store. For wholesale, OEM or export, send the case type, quantity and deadline — kexinMaterials returns a tiered quote and container plan within 24 hours.

Can you build cold-chain or insulated versions?

Yes. We offer PU-foam insulated shells that hold 2–8 °C or -20 °C ranges for short-haul transport when combined with ice packs or phase-change coolant. A mounting pocket and read-out window for a temperature logger can be pre-installed.

Can you support our GDP/GSP validation?

Yes — insulation test data, loading recommendations and validation templates to complete your transport qualification files.

Can it be made lighter for single-person carry?

Yes. Optimizing wall-thickness distribution, using high-flow modified resins and honeycomb ribbing cuts 15–25% of weight while keeping strength, combined with ergonomic handles and a shoulder strap for longer one-person carries.

How long can 2–8°C be maintained?

Depends on model, ice-pack setup and ambient: standard setups hold 48+ hours at 35°C ambient. We provide measured curves for your actual load profile.

Key Terms Explained

ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.
EVA foam insert
Ethylene-vinyl acetate closed-cell foam: dense, resilient, CNC-machinable and resistant to permanent compression set. In protective cases it is cut to the equipment profile and is the preferred lining for precision instruments and high-value gear.
IP67 rating
An ingress protection code from IEC 60529. The first digit 6 means dust-tight; the second digit 7 means no water ingress during 30 minutes at 1 m depth. It is the mainstream sealing benchmark for protective cases covering outdoor, marine and emergency short-immersion use.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Is packing a lens tightly the safest approach?

The opposite is true. Tight packing conducts shell impacts straight into the barrel and blocks moisture from dissipating. Optics should be suspended — a continuous elastic medium with clearance between equipment and shell attenuates shock along the transmission path while allowing airflow and dehumidification.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.