KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Anti-Static ESD Surgical Instrument Case for Photography

Anti-Static ESD Surgical Instrument Case for Photography

Manufacturer

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Anti-Static ESD Surgical Instrument Case for Photography is an engineered protective case in the medical case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Anti-Static ESD Surgical Instrument Case for Photography · Medical & Cold Chain Cases — 客信新材料源头工厂

Anti-Static ESD Surgical Instrument Case for Photography: Product & Manufacturer Overview

The Anti-Static ESD Surgical Instrument Case for Photography can be tailored to your brand and project: case color, silk-print or laser-engraved logo, foam layout and handle/wheel options are all adjustable. kexinMaterials, as the source factory, runs the whole journey from sample approval to mass production, including neutral shipping and OEM private label.

Reliability in a Anti-Static ESD Surgical Instrument Case for Photography comes from structure: kexinMaterials combines PU-foamed insulation walls with sealed shells and dedicated ice-pack bays, holding 2–8°C for 48+ hours under standard load (model and ambient dependent), with mounting points for temperature data loggers.

Key facts: Anti-Static ESD Surgical Instrument Case for Photography sourcing facts: factory-direct from Guangdong, China; sealing up to IP67; service range -40°C to +80°C; CNC-cut EVA interiors; logo printing/engraving; factory audits and third-party QC welcome.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
CushioningFoam sized to allowable G (calculation supplied)

Product Feature Breakdown

ESD-safeInstrumentation

Permanent ESD materials (carbon masterbatch) and topical treatments differ enormously in service life: if Anti-Static ESD Surgical Instrument Case for Photography will be washed and reused repeatedly, specify permanent — topical antistats stop working after a few wipe-downs. kexinMaterials supplies permanent ESD bodies as standard.

When Anti-Static ESD Surgical Instrument Case for Photography carries precision instruments, the shock acceleration limit is normally specified by the instrument maker (commonly 25–50 G). Foam density and deflection travel must be derived from that threshold rather than from habit; kexinMaterials issues a cushioning calculation against a customer-supplied allowable G.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Shell Materials Compared (PP / ABS / PE)

Industry data puts PP (polypropylene) at ~55% of plastic protective-case share — strong chemical resistance, low-temperature toughness and cost efficiency; ABS holds ~30% with harder, glossier surfaces; large thick-wall cases favor rotomolded PE. Plastic/polymer cases together account for 63.7% of the industrial protective case market (2025).

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Product Overview

The kexinMaterials Anti-Static ESD Surgical Instrument Case for Photography is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static ESD Surgical Instrument Case for Photography can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static ESD Surgical Instrument Case for Photography ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static ESD Surgical Instrument Case for Photography passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Anti-Static ESD Surgical Instrument Case for Photography — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Anti-Static ESD Surgical Instrument Case for Photography

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can medical cases be wiped with disinfectant?

Yes. The modified PP/ABS shell tolerates 75% alcohol, chlorine-based and quaternary ammonium disinfectant wipes; avoid prolonged soaking in strong oxidizers. Inserts can be specified as removable, washable EVA or medical-grade foam for routine cleaning.

Can the case be mounted in an ambulance?

Yes. We supply versions with mounting bases or clips that mate with stretcher frames and cabin wall fixings so the case cannot shift in transit, plus anti-slip feet and quick-release straps for carrying once on scene.

Can a data logger be installed?

Yes — a fixed logger bay inside plus an external-read window option, compatible with mainstream USB and Bluetooth loggers.

Can you build cold-chain or insulated versions?

Yes. We offer PU-foam insulated shells that hold 2–8 °C or -20 °C ranges for short-haul transport when combined with ice packs or phase-change coolant. A mounting pocket and read-out window for a temperature logger can be pre-installed.

What disinfection do liners tolerate?

Food-grade EVA and medical PE liners tolerate 75% alcohol and chlorine-based wipes, and lift out for full washing.

Can the interior be zoned by clinical function?

Yes. A common layout separates resuscitation, airway, trauma and pharmacy items with color-coded bands and clear elastic pockets so contents are visible and restocking is orderly. Layouts can be rebuilt around your hospital's protocol, with a checklist printed inside the lid.

Key Terms Explained

ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.
Pick-and-pluck foam
Pre-scored cubed foam that the user tears out cube by cube to form pockets around the equipment. It needs no tooling, ships fast and can be reconfigured, but offers less precision and support than CNC-cut EVA.
IP67 rating
An ingress protection code from IEC 60529. The first digit 6 means dust-tight; the second digit 7 means no water ingress during 30 minutes at 1 m depth. It is the mainstream sealing benchmark for protective cases covering outdoor, marine and emergency short-immersion use.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Is a thick, rigid case enough to protect an instrument?

A rigid shell is only the first layer. Survival is determined by the peak acceleration transmitted to the device and its resonant response — foam that is too firm passes shock straight through and can be worse than a soft case. Size the cushioning from the instrument's allowable G and design away from its natural frequency.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.