KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Anti-Static ESD Medical Case for Police

Anti-Static ESD Medical Case for Police

Manufacturer

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Anti-Static ESD Medical Case for Police is an engineered protective case in the medical case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Anti-Static ESD Medical Case for Police · Medical & Cold Chain Cases — 客信新材料源头工厂

Anti-Static ESD Medical Case for Police: Product & Manufacturer Overview

Reliability in a Anti-Static ESD Medical Case for Police comes from structure: kexinMaterials combines PU-foamed insulation walls with sealed shells and dedicated ice-pack bays, holding 2–8°C for 48+ hours under standard load (model and ambient dependent), with mounting points for temperature data loggers.

For buyers, the true cost of a Anti-Static ESD Medical Case for Police is more than unit price: carton specs shape freight, and spare parts and replenishment shape long-term use. kexinMaterials optimizes container loading and ships wear-part kits with volume orders to lower your total cost of ownership.

Key facts: The Anti-Static ESD Medical Case for Police is manufactured factory-direct by KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials): IP67 options, MOQ 50 pcs on stock models, samples in 7–15 days, production in 15–30 days, exporting to 8 major markets.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)

Product Feature Breakdown

ESD-safe

Permanent ESD materials (carbon masterbatch) and topical treatments differ enormously in service life: if Anti-Static ESD Medical Case for Police will be washed and reused repeatedly, specify permanent — topical antistats stop working after a few wipe-downs. kexinMaterials supplies permanent ESD bodies as standard.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Export Compliance Essentials

EU-bound cases require CE marking and REACH compliance (phthalates such as DEHP/DBP each below 0.1% in soft parts); hard cases sold via Amazon FBA need ISTA 3A transit-drop certification; shipping drones or devices with lithium batteries additionally involves UN38.3 and IATA rules. A legitimate source factory provides these test reports directly.

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Product Overview

The kexinMaterials Anti-Static ESD Medical Case for Police is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static ESD Medical Case for Police can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static ESD Medical Case for Police ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static ESD Medical Case for Police passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Anti-Static ESD Medical Case for Police — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Anti-Static ESD Medical Case for Police

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

How long can 2–8°C be maintained?

Depends on model, ice-pack setup and ambient: standard setups hold 48+ hours at 35°C ambient. We provide measured curves for your actual load profile.

Can medical cases be wiped with disinfectant?

Yes. The modified PP/ABS shell tolerates 75% alcohol, chlorine-based and quaternary ammonium disinfectant wipes; avoid prolonged soaking in strong oxidizers. Inserts can be specified as removable, washable EVA or medical-grade foam for routine cleaning.

Are you a factory or a trading company?

kexinMaterials is a source factory for engineered plastic cases based in Guangdong, China, with injection, rotational and blow molding lines and an in-house tool shop. Factory audits and video tours are welcome.

Can you build cold-chain or insulated versions?

Yes. We offer PU-foam insulated shells that hold 2–8 °C or -20 °C ranges for short-haul transport when combined with ice packs or phase-change coolant. A mounting pocket and read-out window for a temperature logger can be pre-installed.

What compliance requirements apply to medical transport cases?

In China, storage and transport conditions, temperature/humidity records and cleaning are governed by medical device distribution quality rules; exports follow the destination country's registration requirements. As an accessory, the case ships with material safety notes and cleaning validation guidance to support your documentation.

How do I place an order or get a quote?

For retail and small orders, visit our online store. For wholesale, OEM or export, send the case type, quantity and deadline — kexinMaterials returns a tiered quote and container plan within 24 hours.

Key Terms Explained

ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.
Pick-and-pluck foam
Pre-scored cubed foam that the user tears out cube by cube to form pockets around the equipment. It needs no tooling, ships fast and can be reconfigured, but offers less precision and support than CNC-cut EVA.
Rotational molding
A process in which polyethylene powder is heated inside a biaxially rotating mold so the melt coats the cavity evenly. It yields seamless, tough walls, supports double-wall sandwich construction and uses low-cost tooling — ideal for large and oversize cases.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.