KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Anti-Static ESD First Aid Case

Anti-Static ESD First Aid Case

Manufacturer

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Anti-Static ESD First Aid Case is an engineered protective case in the medical case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Anti-Static ESD First Aid Case · Medical & Cold Chain Cases — 客信新材料源头工厂

Anti-Static ESD First Aid Case: Product & Manufacturer Overview

Transporting medical devices, emergency supplies and biological samples demands both physical protection and temperature control. The kexinMaterials Anti-Static ESD First Aid Case range spans first-aid cases, vaccine cold boxes and specimen carriers, built with medical-grade liners and insulated structures for hospitals, CDCs and pharma logistics.

For buyers, the true cost of a Anti-Static ESD First Aid Case is more than unit price: carton specs shape freight, and spare parts and replenishment shape long-term use. kexinMaterials optimizes container loading and ships wear-part kits with volume orders to lower your total cost of ownership.

Key facts: Anti-Static ESD First Aid Case sourcing facts: factory-direct from Guangdong, China; sealing up to IP67; service range -40°C to +80°C; CNC-cut EVA interiors; logo printing/engraving; factory audits and third-party QC welcome.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
Emergency designOne-hand latches, >100° lid, reflective marking

Product Feature Breakdown

ESD-safeEmergency response

ESD performance on Anti-Static ESD First Aid Case is graded by surface resistivity: conductive 10³–10⁵Ω, dissipative 10⁶–10⁹Ω, antistatic 10⁹–10¹¹Ω. Component handling normally calls for the dissipative band, avoiding the high transient current of a fast discharge. kexinMaterials configures to ANSI/ESD S541.

Response cases must work at night and in low visibility: specify high-contrast body colours (orange/yellow) with reflective tape and fluorescent markings on Anti-Static ESD First Aid Case, plus colour-zoned inserts so a missing item is visible at a glance. kexinMaterials offers EN ISO 20471 compliant reflective options.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Shell Materials Compared (PP / ABS / PE)

Industry data puts PP (polypropylene) at ~55% of plastic protective-case share — strong chemical resistance, low-temperature toughness and cost efficiency; ABS holds ~30% with harder, glossier surfaces; large thick-wall cases favor rotomolded PE. Plastic/polymer cases together account for 63.7% of the industrial protective case market (2025).

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Product Overview

The kexinMaterials Anti-Static ESD First Aid Case is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static ESD First Aid Case can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static ESD First Aid Case ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static ESD First Aid Case passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Anti-Static ESD First Aid Case — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Anti-Static ESD First Aid Case

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can it be made lighter for single-person carry?

Yes. Optimizing wall-thickness distribution, using high-flow modified resins and honeycomb ribbing cuts 15–25% of weight while keeping strength, combined with ergonomic handles and a shoulder strap for longer one-person carries.

Can the interior be zoned by clinical function?

Yes. A common layout separates resuscitation, airway, trauma and pharmacy items with color-coded bands and clear elastic pockets so contents are visible and restocking is orderly. Layouts can be rebuilt around your hospital's protocol, with a checklist printed inside the lid.

Can the case be mounted in an ambulance?

Yes. We supply versions with mounting bases or clips that mate with stretcher frames and cabin wall fixings so the case cannot shift in transit, plus anti-slip feet and quick-release straps for carrying once on scene.

How long can 2–8°C be maintained?

Depends on model, ice-pack setup and ambient: standard setups hold 48+ hours at 35°C ambient. We provide measured curves for your actual load profile.

What compliance requirements apply to medical transport cases?

In China, storage and transport conditions, temperature/humidity records and cleaning are governed by medical device distribution quality rules; exports follow the destination country's registration requirements. As an accessory, the case ships with material safety notes and cleaning validation guidance to support your documentation.

Can a data logger be installed?

Yes — a fixed logger bay inside plus an external-read window option, compatible with mainstream USB and Bluetooth loggers.

Key Terms Explained

ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.
Rotational molding
A process in which polyethylene powder is heated inside a biaxially rotating mold so the melt coats the cavity evenly. It yields seamless, tough walls, supports double-wall sandwich construction and uses low-cost tooling — ideal for large and oversize cases.
Gasket
The elastomeric ring—usually silicone or EPDM—seated in the lid-to-base joint. Latch pressure deforms it to fill the mating gap, making it the core component behind an IP67 seal and a replaceable wear part.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Is a rescue case just a tool case with different contents?

The design logic is entirely different. Tool cases optimise volumetric efficiency; rescue cases optimise seconds-to-access and missing-item visibility — one-handed latches, wide lid opening, protocol-ordered layout, colour zoning and inventory windows. In an emergency, not finding an item is more damaging than not carrying it, and that drives the structural difference.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.