KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Anti-Static ESD First Aid Case for Police

Anti-Static ESD First Aid Case for Police

Manufacturer

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Anti-Static ESD First Aid Case for Police is an engineered protective case in the medical case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Anti-Static ESD First Aid Case for Police · Medical & Cold Chain Cases — 客信新材料源头工厂

Anti-Static ESD First Aid Case for Police: Product & Manufacturer Overview

The Anti-Static ESD First Aid Case for Police can be tailored to your brand and project: case color, silk-print or laser-engraved logo, foam layout and handle/wheel options are all adjustable. kexinMaterials, as the source factory, runs the whole journey from sample approval to mass production, including neutral shipping and OEM private label.

For device manufacturers and pharma distributors, kexinMaterials offers OEM programs on the Anti-Static ESD First Aid Case for Police: custom inserts sized to your device, insulation test data for cold-chain validation, and logger accessories for GDP/GSP compliance — one supplier from registration to operations.

Key facts: kexinMaterials builds the Anti-Static ESD First Aid Case for Police across injection, rotational and blow molding lines with in-house tooling (35–45 days), full OEM/ODM programs, and wholesale tiers at 50/200/500/1000 pcs.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
Emergency designOne-hand latches, >100° lid, reflective marking

Product Feature Breakdown

ESD-safeEmergency response

Permanent ESD materials (carbon masterbatch) and topical treatments differ enormously in service life: if Anti-Static ESD First Aid Case for Police will be washed and reused repeatedly, specify permanent — topical antistats stop working after a few wipe-downs. kexinMaterials supplies permanent ESD bodies as standard.

In emergency response, access speed is the primary metric for Anti-Static ESD First Aid Case for Police: latches must work one-handed with gloves, the lid must open beyond 100° so it cannot fall back, and the insert must be laid out by treatment protocol rather than item category. kexinMaterials builds the retrieval sequence around a customer's own SOP.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Export Compliance Essentials

EU-bound cases require CE marking and REACH compliance (phthalates such as DEHP/DBP each below 0.1% in soft parts); hard cases sold via Amazon FBA need ISTA 3A transit-drop certification; shipping drones or devices with lithium batteries additionally involves UN38.3 and IATA rules. A legitimate source factory provides these test reports directly.

Extreme Temperature Performance

Engineering-grade cases typically operate from -30°C to +80°C (military testing follows MIL-STD-810H Methods 501.7/502.7 for temperature and 503.7 for thermal shock, cycling as wide as -40°C↔+71°C). For cold climates choose PP copolymer or PE shells — standard ABS embrittles at low temperatures.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Product Overview

The kexinMaterials Anti-Static ESD First Aid Case for Police is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static ESD First Aid Case for Police can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static ESD First Aid Case for Police ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static ESD First Aid Case for Police passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Anti-Static ESD First Aid Case for Police — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Anti-Static ESD First Aid Case for Police

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can a data logger be installed?

Yes — a fixed logger bay inside plus an external-read window option, compatible with mainstream USB and Bluetooth loggers.

What disinfection do liners tolerate?

Food-grade EVA and medical PE liners tolerate 75% alcohol and chlorine-based wipes, and lift out for full washing.

How do I place an order or get a quote?

For retail and small orders, visit our online store. For wholesale, OEM or export, send the case type, quantity and deadline — kexinMaterials returns a tiered quote and container plan within 24 hours.

Can medical cases be wiped with disinfectant?

Yes. The modified PP/ABS shell tolerates 75% alcohol, chlorine-based and quaternary ammonium disinfectant wipes; avoid prolonged soaking in strong oxidizers. Inserts can be specified as removable, washable EVA or medical-grade foam for routine cleaning.

Can the interior be zoned by clinical function?

Yes. A common layout separates resuscitation, airway, trauma and pharmacy items with color-coded bands and clear elastic pockets so contents are visible and restocking is orderly. Layouts can be rebuilt around your hospital's protocol, with a checklist printed inside the lid.

Can first-aid interiors be configured per department?

Yes. Modular trays are arranged to your supply checklist, with department marking and numbering options.

Key Terms Explained

ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.
MIL-STD-810
A US Department of Defense standard for environmental engineering considerations and laboratory tests, defining procedures for drop, vibration, thermal shock, salt fog and humidity. Protective cases are commonly validated against Method 516 (shock) and Method 514 (vibration).
Pressure equalization valve
A one-way breather fitted to the case wall that lets air pass slowly while blocking water and dust. It balances internal and external pressure during air freight or altitude change, preventing a vacuum-locked lid or a deformed gasket.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Is a rescue case just a tool case with different contents?

The design logic is entirely different. Tool cases optimise volumetric efficiency; rescue cases optimise seconds-to-access and missing-item visibility — one-handed latches, wide lid opening, protocol-ordered layout, colour zoning and inventory windows. In an emergency, not finding an item is more damaging than not carrying it, and that drives the structural difference.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.