KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Medical & Cold Chain Cases › Anti-Static ESD Diagnostic Case for Instruments

Anti-Static ESD Diagnostic Case for Instruments

Manufacturer

Temperature and protection assurance for the chain of life · Factory direct · Wholesale / OEM / Global supply

Anti-Static ESD Diagnostic Case for Instruments is an engineered protective case in the medical case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

A medical equipment case carries first-aid, diagnostic and sampling devices with hygienic, easy-clean materials and custom dividers for fast pre-hospital and field response.

Anti-Static ESD Diagnostic Case for Instruments · Medical & Cold Chain Cases — 客信新材料源头工厂

Anti-Static ESD Diagnostic Case for Instruments: Product & Manufacturer Overview

For device manufacturers and pharma distributors, kexinMaterials offers OEM programs on the Anti-Static ESD Diagnostic Case for Instruments: custom inserts sized to your device, insulation test data for cold-chain validation, and logger accessories for GDP/GSP compliance — one supplier from registration to operations.

The Anti-Static ESD Diagnostic Case for Instruments can be tailored to your brand and project: case color, silk-print or laser-engraved logo, foam layout and handle/wheel options are all adjustable. kexinMaterials, as the source factory, runs the whole journey from sample approval to mass production, including neutral shipping and OEM private label.

Key facts: Anti-Static ESD Diagnostic Case for Instruments sourcing facts: factory-direct from Guangdong, China; sealing up to IP67; service range -40°C to +80°C; CNC-cut EVA interiors; logo printing/engraving; factory audits and third-party QC welcome.

Key Specifications

Shell materialModified PP / PE with PU foam insulation
Temperature hold2–8°C / 15–25°C with ice packs (validated per model)
Protection ratingIP67
LinerFood-grade EVA / medical PE, disinfectable
MonitoringLogger bay, humidity indicator options
ComplianceGDP/GSP cold-chain validation support
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)
CushioningFoam sized to allowable G (calculation supplied)

Product Feature Breakdown

ESD-safeInstrumentation

Permanent ESD materials (carbon masterbatch) and topical treatments differ enormously in service life: if Anti-Static ESD Diagnostic Case for Instruments will be washed and reused repeatedly, specify permanent — topical antistats stop working after a few wipe-downs. kexinMaterials supplies permanent ESD bodies as standard.

When Anti-Static ESD Diagnostic Case for Instruments carries precision instruments, the shock acceleration limit is normally specified by the instrument maker (commonly 25–50 G). Foam density and deflection travel must be derived from that threshold rather than from habit; kexinMaterials issues a cushioning calculation against a customer-supplied allowable G.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
Clean linerXLPE cross-linked foam, non-shedding, disinfectableGeneric foam sheds onto instruments
TemperatureOptional insulation + ice-pack bay, 2–8°C short holdNo control, cold chain breaks
RatingIP67, blocks liquid ingressPlain cases not waterproof
LabelingBiohazard/sharps silkscreen supportedNo professional marking
MOQFrom 50 pcs, infection-control customMostly off-the-shelf
CertificationMaterial & REACH docs providedIncomplete compliance

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

IP Ratings (IEC 60529)

In IP67, the “6” means dust-tight (no dust ingress after a 2 kPa vacuum dust test) and the “7” means temporary immersion: the enclosure survives 30 minutes at 1 m depth with its highest point at least 150 mm below the surface, per IEC 60529 Clause 14.2.7.

Export Compliance Essentials

EU-bound cases require CE marking and REACH compliance (phthalates such as DEHP/DBP each below 0.1% in soft parts); hard cases sold via Amazon FBA need ISTA 3A transit-drop certification; shipping drones or devices with lithium batteries additionally involves UN38.3 and IATA rules. A legitimate source factory provides these test reports directly.

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Typical Applications

  • Vaccine and biologics cold-chain delivery
  • Ambulance and pre-hospital emergency kits
  • Inter-lab biological specimen transfer
  • Clinical trial material logistics
  • Disaster medical relief pre-positioning
  • Corporate and household first-aid storage

Product Overview

The kexinMaterials Anti-Static ESD Diagnostic Case for Instruments is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static ESD Diagnostic Case for Instruments can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static ESD Diagnostic Case for Instruments ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static ESD Diagnostic Case for Instruments passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

Cold-chain bodies are double-walled and PU-foamed in one operation for gap-free insulation; first-aid cases are lightweight injection molded with modular interiors. Cold models ship with measured temperature-hold curves for your validation files.

Medical & Cold Chain Cases · Anti-Static ESD Diagnostic Case for Instruments — 客信新材料 kexinMaterials
Medical & Cold Chain Cases · Anti-Static ESD Diagnostic Case for Instruments

Field Case Studies

Disease-control center

1,500 vaccine cold-chain cases with XLPE liner and ice-pack bay holding 2–8°C short-term; passed infection-control acceptance.

Medical-device distributor

2,200 surgical-instrument transit cases with biohazard silkscreen and full REACH documentation.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can you build cold-chain or insulated versions?

Yes. We offer PU-foam insulated shells that hold 2–8 °C or -20 °C ranges for short-haul transport when combined with ice packs or phase-change coolant. A mounting pocket and read-out window for a temperature logger can be pre-installed.

Can it be made lighter for single-person carry?

Yes. Optimizing wall-thickness distribution, using high-flow modified resins and honeycomb ribbing cuts 15–25% of weight while keeping strength, combined with ergonomic handles and a shoulder strap for longer one-person carries.

Are you a factory or a trading company?

kexinMaterials is a source factory for engineered plastic cases based in Guangdong, China, with injection, rotational and blow molding lines and an in-house tool shop. Factory audits and video tours are welcome.

Can first-aid interiors be configured per department?

Yes. Modular trays are arranged to your supply checklist, with department marking and numbering options.

What compliance requirements apply to medical transport cases?

In China, storage and transport conditions, temperature/humidity records and cleaning are governed by medical device distribution quality rules; exports follow the destination country's registration requirements. As an accessory, the case ships with material safety notes and cleaning validation guidance to support your documentation.

Can the case be mounted in an ambulance?

Yes. We supply versions with mounting bases or clips that mate with stretcher frames and cabin wall fixings so the case cannot shift in transit, plus anti-slip feet and quick-release straps for carrying once on scene.

Key Terms Explained

ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.
Injection molding
Molten plastic is injected under high pressure into a steel mold and cooled. It delivers tight tolerances, fine surface finish and fast cycles at low piece cost, but requires higher tooling investment — best for volume production of small and mid-size cases.
OEM / ODM
OEM means manufacturing to the customer's design under the customer's brand; ODM means the factory designs the product and the customer rebrands it. In case sourcing, private-labeling an existing shell is OEM, while commissioning a new shell and interior design is closer to ODM.

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Is a thick, rigid case enough to protect an instrument?

A rigid shell is only the first layer. Survival is determined by the peak acceleration transmitted to the device and its resonant response — foam that is too firm passes shock straight through and can be worse than a soft case. Size the cushioning from the instrument's allowable G and design away from its natural frequency.

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.