KeXin New Materials (Guangdong) Co., Ltd. · Source Case FactoryOnline store: www.beeaa.com
Get a Quote
Home › Precision Instrument Cases › Anti-Static Calibration Case for Medical

Anti-Static Calibration Case for Medical

Manufacturer

Lab-grade protection, wherever the field work is · Factory direct · Wholesale / OEM / Global supply

Anti-Static Calibration Case for Medical is an engineered protective case in the instrument case family: built by source factory kexinMaterials with IP67 sealing, impact-resistant PP copolymer or rotomolded PE shells and CNC-cut custom foam; wholesale, OEM and export supported.

Key definition

An instrument case protects precision measuring and testing equipment in transit, emphasizing shock absorption, moisture resistance and custom foam so instruments stay calibrated between lab and field.

Anti-Static Calibration Case for Medical · Precision Instrument Cases — 客信新材料源头工厂

Anti-Static Calibration Case for Medical: Product & Manufacturer Overview

The Anti-Static Calibration Case for Medical can be tailored to your brand and project: case color, silk-print or laser-engraved logo, foam layout and handle/wheel options are all adjustable. kexinMaterials, as the source factory, runs the whole journey from sample approval to mass production, including neutral shipping and OEM private label.

From total stations and spectrometers to flaw detectors, kexinMaterials has built the Anti-Static Calibration Case for Medical for thousands of instrument models, with an insert database spanning surveying, environmental monitoring, NDT and telecom engineering.

Key facts: The Anti-Static Calibration Case for Medical is manufactured factory-direct by KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials): IP67 options, MOQ 50 pcs on stock models, samples in 7–15 days, production in 15–30 days, exporting to 8 major markets.

Key Specifications

Shell materialModified PP / ABS / aluminum-frame composite
Protection ratingIP67
InteriorCustom EVA / PU foam / anti-static foam
Pressure reliefAutomatic equalization valve (air freight ready)
FitsSurveying, testing, analysis, telecom, metrology instruments
OptionsHumidity indicator, desiccant chamber, nameplate, co-packing
ESDSurface resistivity 10⁶–10⁹Ω (permanent, ANSI/ESD S541)

Product Feature Breakdown

ESD-safe

Permanent ESD materials (carbon masterbatch) and topical treatments differ enormously in service life: if Anti-Static Calibration Case for Medical will be washed and reused repeatedly, specify permanent — topical antistats stop working after a few wipe-downs. kexinMaterials supplies permanent ESD bodies as standard.

How kexinMaterials Compares

DimensionkexinMaterialsGeneric market cases
ProtectionIP67, thermal-shock verified -40°C↔+71°CPlain cases fail thermal shock
Damping foamEVA/PU/XLPE CNC-cut to instrument shapeGeneric foam under-cushions
ESD & cleanOptional anti-static liner, non-shedding XLPESheds debris onto optics
RigidityABS high surface hardness, high crush strengthPP softens under stacking
MOQFrom 50 pcs, non-standard sizes toolableOften 500 pcs min
CertificationDrop/vibration test reports providedIncomplete docs

ESD protection: interior materials hold surface resistance in the 10^6–10^9 ohm range, with conductive shell compounds optional, protecting PCBs and static-sensitive devices.

Standards & Industry Data

Foam Inserts (EVA / PU / XLPE)

Three insert materials dominate: EVA (closed-cell, waterproof, firm support for precision instruments), PU foam (open-cell, soft cushioning, economical) and XLPE (chemically inert, non-shedding — preferred for medical and optics). CNC pockets are cut from the equipment's 3D data; drawing-to-first-sample typically takes 1–2 weeks.

Shell Materials Compared (PP / ABS / PE)

Industry data puts PP (polypropylene) at ~55% of plastic protective-case share — strong chemical resistance, low-temperature toughness and cost efficiency; ABS holds ~30% with harder, glossier surfaces; large thick-wall cases favor rotomolded PE. Plastic/polymer cases together account for 63.7% of the industrial protective case market (2025).

Military Vibration (MIL-STD-810H, Method 514.8)

Random-vibration testing spans 20–2,000 Hz to replicate truck, aircraft and battlefield vibration, run for hours per axis; transport spectra cover 2–500 Hz. Passing means the shell-plus-foam system protects precision payloads through long multimodal transit.

Typical Applications

  • Surveying instrument field carry
  • Third-party lab on-site sampling
  • Metrology equipment calibration logistics
  • Fiber-optic construction toolkits
  • Laboratory relocation and equipment loans
  • Manufacturer co-packing programs

Product Overview

The kexinMaterials Anti-Static Calibration Case for Medical is one-piece molded from engineering plastics, balancing impact strength, sealing and long-term durability — available from stock or fully customized. Key specs below.

On process: the Anti-Static Calibration Case for Medical can be injection, rotational or blow molded. Injection gives precise sealing and repeatability; rotomolding yields large seamless shells with thick-wall toughness; blow molding suits light, economical builds. kexinMaterials runs all three lines and matches the process to your protection grade and budget.

For interior protection, the Anti-Static Calibration Case for Medical ships with or accepts CNC-cut EVA/PE foam, routed to your equipment's 3D data so nothing shifts in transit; precision instruments can add ESD-safe or cushioned layered structures.

On quality, the Anti-Static Calibration Case for Medical passes batch drop, stack and immersion checks; key models can be tested to MIL-STD-810H for drop and vibration, with material and third-party test reports supplied for export and industry acceptance.

Manufacturing Process

High-pressure injection molding keeps shell tolerances tight for reliable sealing, and inserts are CNC-cut after drop-simulation checks. Volume co-packing projects follow a PDI inspection routine so cushioning performance stays consistent across batches.

Precision Instrument Cases · Anti-Static Calibration Case for Medical — 客信新材料 kexinMaterials
Precision Instrument Cases · Anti-Static Calibration Case for Medical

Field Case Studies

Metrology institute

600 anti-static liner cases for precision calibrators using non-shedding XLPE; zero scratch incidents in annual off-site checks.

Industrial-sensor maker

3,000 cases CNC-cut to probe shapes, thermal-shock verified -40°C↔+71°C, protecting gear across overseas expos.

About kexinMaterials

KeXin New Materials (Guangdong) Co., Ltd. (brand: kexinMaterials) is a source factory for engineered plastic cases based in Guangdong, China, operating injection, rotational and blow molding lines with an in-house tool shop. Nine product series serve buyers worldwide — from military and drone cases to medical, photography and business lines.

Why kexinMaterials: factory-direct pricing with no middle-man margin; three molding processes under one roof; in-house tooling for controlled lead times; batch drop and seal testing; factory audits, samples-first and third-party QC all supported.

Frequently Asked Questions

Can the case be made moisture-proof or hold desiccant?

Yes. We commonly mold a desiccant pocket into the insert and combine it with IP67 sealing for long-term dryness. For high-value stored instruments we can add humidity indicator cards or a breather-valve version so you can read the internal condition at a glance.

MOQ and lead time?

50 pcs for stock sizes with 7-day dispatch; custom inserts 15–20 days; new tooling 35–45 days.

How do you protect an instrument's display panel?

The insert is relieved above the screen so nothing touches the display — load is carried only on the chassis frame, preventing lid pressure from reaching the glass. A soft pad can be added in the lid for two-way protection where needed.

How do I place an order or get a quote?

For retail and small orders, visit our online store. For wholesale, OEM or export, send the case type, quantity and deadline — kexinMaterials returns a tiered quote and container plan within 24 hours.

How is a custom insert made?

Send 3D data, dimensioned photos or a sample unit. We design the cutout layout, confirm an insert sample with you, then run production. Common models ship from existing data.

Do you offer anti-static interiors?

Yes — anti-static foam and conductive EVA with surface resistance in the 10^6–10^9 ohm range for PCBs and electronic modules.

Key Terms Explained

ESD / antistatic
Conductive masterbatch or antistatic lining brings surface resistance into the 10^6–10^9 Ω range so static cannot build up and damage electronics. It is a routine requirement in electronics manufacturing, semiconductor and precision instrument handling.
EVA foam insert
Ethylene-vinyl acetate closed-cell foam: dense, resilient, CNC-machinable and resistant to permanent compression set. In protective cases it is cut to the equipment profile and is the preferred lining for precision instruments and high-value gear.
MIL-STD-810
A US Department of Defense standard for environmental engineering considerations and laboratory tests, defining procedures for drop, vibration, thermal shock, salt fog and humidity. Protective cases are commonly validated against Method 516 (shock) and Method 514 (vibration).

Common Misconceptions

Is any black plastic case an ESD case?

Colour proves nothing. Black is merely a by-product of carbon masterbatch; the market is full of ordinary black ABS/PP cases with no ESD property, while pink and blue dissipative cases also exist. The only reliable check is a surface-resistivity meter reading or a third-party ESD test report.

Related Keywords

Need wholesale or custom cases?

kexinMaterials quotes factory-direct — confirm samples before mass production.

Visit Our Store

Certifications & Compliance

Materials are RoHS- and REACH-compliant, with CE marking and market-specific compliance files available on request. Sealing is verified to IP67 (IEC 60529), and we supply MIL-STD-810H transit-drop and vibration test documentation plus third-party immersion/drop test reports, with factory audits and incoming QC welcome.